Used Pharmaceutical Machinery: Which GMP Documents Should You Ask For?
Pre-owned pharma equipment - rotary tablet presses, RMGs, FBDs, coaters, capsule fillers and blister machines - is a smart way for formulation SMEs and contract manufacturers to add capacity. The machine is only half the purchase; the documentation decides how fast you can qualify it.
Documents to request
- Material certificates for product-contact parts (SS316 / SS316L) and surface-finish records.
- Design, installation and operational qualification (DQ/IQ/OQ) copies from the original installation.
- Calibration records for critical instruments and the latest preventive-maintenance log.
- Manuals, P&IDs, electrical drawings and spare-parts lists.
- For PLC/HMI machines, confirmation of audit-trail and user-level features if you need 21 CFR Part 11 / Annex 11 compliance.
Physical checks
Inspect contact surfaces for pitting, weld discolouration and scratches; check gaskets and seals; confirm change parts and tooling for your product sizes; and run the machine empty to check noise and vibration.
Plan for re-qualification
Used equipment must be qualified for its new use at your site. Budget for IQ/OQ/PQ, cleaning validation and any SOP updates.